UPS GT S 11 10kVA/10kW SC On-Line 1F Rack/Tower 2U
- Power 10000 VA / 10000 W
- Waveform sine wave
- Power factor (PF) 1
| Power | 10000 VA / 10000 W |
| Topology (IEC 62040-3) | On-line double conversion (VFI-SS-111) |
| Form factor | Rack 19" / Tower, 2U |
| INPUT | |
| Phases | 1 |
| Nominal voltage | 220 / 230 / 240 V |
| Voltage range | 110–275 V |
| Nominal frequency | 50 / 60 Hz (auto-sensing) |
| Frequency range | 40–70 Hz |
| Input power factor | ≥ 0.995 |
| Current distortion (THDi) | < 3% |
| Input connection | 1P + N + PE (terminal block) |
| Earthing system | TN-S / TN-C / TN-C-S / TT |
| Bypass | internal electronic; external manual (optional) |
| OUTPUT | |
| Output voltage | 220 / 230 / 240 V (configurable) |
| Voltage accuracy | ±1% |
| Output frequency | 50 / 60 Hz |
| Waveform | sine wave |
| Power factor (PF) | 1 |
| Crest factor (CF) | 3:1 |
| Voltage distortion (THDu) | ≤ 1% |
| Overload capacity (line mode) | 100–105%: continuous; 105–125%: transfer to bypass after 10 min; 125–150%: transfer to bypass after 30 s; > 150%: transfer to bypass after 500 ms |
| Output connection | terminal block 1P + N + PE + 2 x IEC 60320 C13 |
| BATTERIES | |
| Battery technology | VRLA / AGM |
| Battery voltage | 240 V DC (optionally 192–240 V DC) |
| Internal batteries | none – external EBM/STB only (16–20 x 12 V) |
| Backup time* | depends on EBM/STB |
| Charging current | 13 A |
| EFFICIENCY AND FUNCTIONS | |
| Efficiency | ≤ 95% |
| Efficiency (ECO mode) | ≤ 98% |
| Transfer time | mains ↔ battery: 0 ms; mains ↔ bypass: 4 ms |
| Cold start | cold start, soft start |
| Frequency converter mode | yes (CVCF) |
| EPO connector | yes |
| Protections | short-circuit, overvoltage, overload, overtemperature |
| Alarms | overload, battery mode, low battery, fan failure |
| Parallel operation | up to 3 units (common or separate batteries) |
| EMC | PN-EN IEC 62040-2, C3 |
| COMMUNICATION | |
| Control panel | rotatable (90°) LCD display |
| Menu languages | 8, including Polish |
| Communication ports | USB (HID) / RS232 (DB9) / dry contacts / Intelligent Slot |
| Optional cards | Intelligent Slot cards: WEB/SNMP, RS485, MODBUS, dry contacts |
| Operating systems | MS Windows / Linux / Unix / MacOS, VMware ESXi, Hyper-V |
| ENCLOSURE AND ENVIRONMENT | |
| Dimensions (W x H x D) | 438 x 86.2 (2U) x 573 mm |
| Weight without batteries | 15.5 kg |
| Ingress protection | IP20 |
| Colour | black |
| Operating temperature | 0–40 °C |
| Humidity | 0–95% (non-condensing) |
| Operating altitude | up to 1000 m a.s.l. without derating; 1000–3000 m: -1% per 100 m |
| Noise level (1 m) | < 55 dB |
GT S 11 10kVA is a single-phase on-line double-conversion UPS (VFI-SS-111) with unity power factor and terminal block connections. Up to three units can be paralleled for more power or N+1 redundancy.
It is suited to server rooms, laboratories, security systems, industrial automation and sites that require long backup times from external batteries.
Yes, up to 3 units, with common or separate battery sets.
Technical data according to the GT UPS datasheet (version 01.26). Please consult our Sales Department before ordering.