UPS GT S 11 IoT 1kVA/1kW On-Line 1F Rack/Tower 2U
- Power 1000 VA / 1000 W
- Waveform sine wave
- Power factor (PF) 1
| Power | 1000 VA / 1000 W |
| Topology (IEC 62040-3) | On-line double conversion (VFI-SS-313) |
| Form factor | Rack 19" / Tower, 2U |
| INPUT | |
| Phases | 1 |
| Nominal voltage | 200 / 208 / 220 / 230 / 240 V |
| Voltage range | 110–300 V |
| Nominal frequency | 50 / 60 Hz (auto-sensing) |
| Frequency range | 40–70 Hz |
| Input power factor | ≥ 0.99 |
| Current distortion (THDi) | < 3% |
| Input connection | IEC 60320 C14 (10 A) |
| Earthing system | TN-S / TN-C / TN-C-S / TT |
| Bypass | internal electronic; external manual (optional) |
| OUTPUT | |
| Output voltage | 200 / 208 / 220 / 230 / 240 V (configurable) |
| Voltage accuracy | ±1% |
| Output frequency | 50 / 60 Hz |
| Waveform | sine wave |
| Power factor (PF) | 1 |
| Crest factor (CF) | 3:1 |
| Voltage distortion (THDu) | ≤ 1% |
| Overload capacity (line mode) | 100–105%: continuous; 106–125%: transfer to bypass after 5 min; 126–150%: transfer to bypass after 30 s; > 151%: transfer to bypass after 750 ms |
| Overload capacity (battery mode) | 100–105%: continuous; 106–125%: shutdown after 3 min; 126–150%: shutdown after 10 s; > 151%: shutdown after 550 ms |
| Output sockets | 8 x IEC 60320 C13 |
| BATTERIES | |
| Battery technology | VRLA / AGM |
| Internal batteries | 3 x 12 V / 7 Ah |
| Battery voltage | 36 V DC |
| Backup time* | ≈ 9 min |
| Hot-swappable batteries | yes |
| External battery modules (EBM) | yes (optional), EBM/STB with auto-detection |
| Charging current | 1.8 A |
| Recharge time | approx. 3 h to 90% capacity |
| EFFICIENCY AND FUNCTIONS | |
| Efficiency | ≤ 91% |
| Efficiency (ECO mode) | ≤ 97% |
| Transfer time | mains ↔ battery: 0 ms; mains ↔ bypass: 4 ms; ECO ↔ inverter: 10 ms |
| Cold start | cold start, soft start |
| Frequency converter mode | yes (CVCF) |
| EPO connector | yes |
| Protections | short-circuit, overvoltage, overload, overtemperature |
| Alarms | overload, battery mode, low battery, fan failure |
| Parallel operation | no |
| Cooling | active, PWM-controlled |
| EMC | PN-EN IEC 62040-2, C2 |
| COMMUNICATION | |
| Control panel | rotatable (90°) LCD display, 4 LEDs, 5 buttons |
| Menu languages | 8, including Polish |
| Communication ports | USB (HID) / RS232 (DB9) / dry contacts / RJ45 (IoT) / Intelligent Slot |
| Optional cards | Intelligent Slot cards: WEB/SNMP, RS485, MODBUS, dry contacts, WiFi |
| Protocols (with card) | HTTP(S), SNMP, Modbus RTU/TCP, MQTT, SSH, NTP, SMTP, Syslog, RADIUS, LDAP, 802.1X |
| Operating systems | MS Windows / Linux / Unix / MacOS, VMware ESXi, Hyper-V |
| ENCLOSURE AND ENVIRONMENT | |
| Dimensions (W x H x D) | 438 x 85.5 (2U) x 445 mm |
| Weight with batteries | 14.3 kg |
| Ingress protection | IP20 |
| Colour | black |
| Operating temperature | 0–40 °C |
| Humidity | 0–95% (non-condensing) |
| Operating altitude | up to 1000 m a.s.l. without derating; 1000–3000 m: -1% per 100 m |
| Noise level (1 m) | < 45 dB |
* Backup time at 75% load and PF=0.8. Actual runtime depends on load, temperature and battery condition.
GT S 11 IoT 1kVA is an on-line double-conversion UPS (VFI-SS-313) with an output power factor of 1, so real power equals apparent power: 1000 W. The load is permanently supplied by the inverter and transfer to battery is seamless (0 ms). Efficiency reaches 97% in ECO mode.
The RJ45 (IoT) port and Intelligent Slot cards integrate the UPS with BMS, DCIM, SCADA and SIEM systems (incl. SNMP, Modbus TCP, MQTT). The rotatable LCD supports 8 languages. Batteries are replaced from the front without powering down the load.
An on-line UPS continuously generates the output voltage in its inverter, so the load is isolated from outages and mains disturbances (0 ms transfer). A line-interactive UPS switches to battery only after detecting a failure, within a few milliseconds.
You can connect external battery modules (EBM, 36 V DC); the UPS detects them automatically. Estimate runtime for your load in the UPS calculator.
Technical data according to the GT UPS datasheet (version 01.26). Please consult our Sales Department before ordering.
Karta Katalogowa GT S 11 1-3kVA RT PF1.pdf