UPS GT S 33 Pro Tower 20kVA/20kW On-Line 3F/3F
- Power 20 kVA / 20 kW
- Waveform sine wave
- Power factor (PF) 1
| Power | 20 kVA / 20 kW |
| Topology (IEC 62040-3) | On-line double conversion (VFI-SS-111) |
| Form factor | free-standing Tower |
| INPUT | |
| Phases | 3 |
| Nominal voltage | 380 / 400 / 415 V |
| Voltage range | 110–498 V |
| Nominal frequency | 50 / 60 Hz (auto-sensing) |
| Frequency range | 40–72 Hz |
| Input power factor | ≥ 0.99 |
| Current distortion (THDi) | ≤ 3% |
| Input connection | 3P + N + PE (terminal block) |
| Earthing system | TN-S / TN-C / TN-C-S / TT |
| BYPASS | |
| Bypass | separate bypass input |
| Bypass voltage range | 187–498 V |
| Input connection | 3P + N (terminal block) |
| OUTPUT | |
| Phases | 3 |
| Output voltage | 380 / 400 / 415 V (configurable) |
| Voltage accuracy | ±1% (balanced load), ±2% (unbalanced load) |
| Output frequency | 50 / 60 Hz ±0.1% (battery mode) |
| Waveform | sine wave |
| Power factor (PF) | 1 |
| Crest factor (CF) | 3:1 |
| Voltage distortion (THDu) | ≤ 1% |
| Overload capacity | 102–110%: transfer to bypass after 60 min; 111–125%: transfer to bypass after 10 min; 126–150%: transfer to bypass after 60 s; > 151%: transfer to bypass after 0.2 s |
| Output connection | 3P + N + PE (terminal block) |
| BATTERIES | |
| Battery technology | VRLA / AGM / NiCd / Li-ion |
| Battery voltage | 480 V DC (VRLA/AGM), range 313–607 V DC |
| Internal batteries | 40 or 80 x 12 V / 7–10 Ah (VRLA/AGM) |
| Backup time* | ≈ 7 min (40 x 9 Ah) / ≈ 19 min (80 x 9 Ah) |
| Compatible EBM | GTS33BP140-1409 |
| Backup time with 1 EBM* | ≈ 69 min |
| Charging current | 20 A |
| EFFICIENCY AND FUNCTIONS | |
| Efficiency | ≤ 96% |
| Efficiency (ECO mode) | ≤ 99% |
| Transfer time | synchronised transfer: 0 ms |
| Cold start | cold start, soft start |
| Frequency converter mode | yes (CVCF) |
| EPO connector | yes |
| Protections | short-circuit, overvoltage, overload, overtemperature |
| Alarms | overload, bypass mode, battery mode, low battery, fan failure |
| Parallel operation | up to 4 units |
| EMC | PN-EN IEC 62040-2 |
| COMMUNICATION | |
| Control panel | LED + 5" LCD touch screen |
| Menu languages | 10, including Polish |
| Communication ports | USB / RS232 (DB9) / dry contacts / 2 x Intelligent Slot (hot-swap) |
| Optional cards | Intelligent Slot cards: WEB/SNMP, RS485, MODBUS, dry contacts |
| ENCLOSURE AND ENVIRONMENT | |
| Dimensions (W x H x D) | 500 x 860 x 887 mm |
| Weight without batteries | 134 kg |
| Weight with batteries | 230 kg (40 pcs) / 326 kg (80 pcs) |
| Ingress protection | IP20 |
| Colour | black |
| Operating temperature | 0–40 °C |
| Humidity | 5–95% (non-condensing) |
| Operating altitude | up to 1500 m a.s.l. without derating |
| Noise level (1 m) | ≤ 55 dB |
* Backup time at 75% load and PF=0.8. Actual runtime depends on load, temperature and battery condition.
GT S 33 Pro Tower 20kVA is a three-phase on-line double-conversion UPS (VFI-SS-111) with unity power factor, delivering 20 kW of real power. It has separate rectifier and bypass inputs, supports VRLA/AGM, NiCd and lithium-ion batteries and can operate as a frequency converter.
Up to four units can be paralleled for more power or N+1 redundancy. Up to 99% efficiency in ECO mode reduces energy and cooling costs.
With the GTS33BP140-1409 battery module approx. 69 min at 75% load. Runtime can be extended with additional battery cabinets – contact us for a configuration.
Yes. The UPS supports VRLA/AGM, NiCd and lithium-ion batteries.
Technical data according to the GT UPS datasheet (version 01.26). Please consult our Sales Department before ordering.