UPS GT S 33 Rack/Tower 20kVA/20kW On-Line 3F/3F
- Power 20 kVA / 20 kW
- Waveform sine wave
- Power factor (PF) 1
| Power | 20 kVA / 20 kW |
| Topology (IEC 62040-3) | On-line double conversion (VFI-SS-111) |
| Form factor | Rack 19" 3U / Tower |
| INPUT | |
| Phases | 3 |
| Nominal voltage | 380 / 400 / 415 V |
| Voltage range | 304–478 V |
| Rated current | 39 A |
| Nominal frequency | 50 / 60 Hz (auto-sensing) |
| Frequency range | 40–70 Hz |
| Input power factor | ≥ 0.99 |
| Current distortion (THDi) | < 3% |
| Input connection | 3P + N + PE (terminal block) |
| Earthing system | TN-S / TN-C / TN-C-S / TT |
| BYPASS | |
| Bypass | separate bypass input |
| Bypass voltage range | -20% / +15% |
| Frequency range | ±1 / ±3 / ±5 Hz |
| OUTPUT | |
| Phases | 3 |
| Output voltage | 380 / 400 / 415 V (configurable) |
| Output current | 30 A |
| Voltage accuracy | ±1% |
| Output frequency | 50 / 60 Hz ±0.1 Hz (battery mode) |
| Waveform | sine wave |
| Power factor (PF) | 1 |
| Crest factor (CF) | 3:1 |
| Voltage distortion (THDu) | ≤ 1% |
| Overload capacity | 101–110%: transfer to bypass after 60 min; 110–125%: transfer to bypass after 10 min; 125–150%: transfer to bypass after 1 min; > 150%: transfer to bypass after 0.2 s |
| Output connection | 3P + N + PE (terminal block) |
| BATTERIES | |
| Battery technology | VRLA / AGM |
| Battery voltage | 240 V DC (192 / 216 V DC) |
| Internal batteries | none – external EBM/STB only |
| Compatible EBM | UPSGTS31EMBRT 209 |
| Backup time with 2 EBM* | ≈ 7 min |
| Backup time with 4 EBM* | ≈ 19 min |
| Charging current | 10 A |
| EFFICIENCY AND FUNCTIONS | |
| Efficiency | ≤ 95% |
| Efficiency (ECO mode) | ≤ 98% |
| Transfer time | synchronised transfer: 0 ms |
| Frequency converter mode | yes (CVCF) |
| EPO connector | yes |
| Protections | short-circuit, overload, overtemperature |
| Alarms | overload, battery mode, low battery, fan failure |
| Parallel operation | up to 4 units |
| EMC | PN-EN IEC 62040-2, C3 |
| COMMUNICATION | |
| Control panel | LED + 5" LCD touch screen |
| Menu languages | Polish, English |
| Communication ports | USB / RS232 / RS485 / dry contacts / Intelligent Slot |
| Optional cards | Intelligent Slot cards: WEB/SNMP, RS485, MODBUS, dry contacts |
| ENCLOSURE AND ENVIRONMENT | |
| Dimensions (W x H x D) | 440 x 130 (3U) x 660 mm |
| Weight without batteries | 24 kg |
| Ingress protection | IP20 |
| Colour | black RAL 7021 |
| Operating temperature | 0–40 °C |
| Humidity | 0–95% (non-condensing) |
| Noise level (1 m) | < 60 dB |
* Backup time at 75% load and PF=0.8. Actual runtime depends on load, temperature and battery condition.
GT S 33 20kVA is a three-phase on-line double-conversion UPS (VFI-SS-111) rated 20 kVA / 20 kW in a 19" 3U rack / tower enclosure. It has a separate bypass input, a 5" touch screen with Polish and English menus and can operate as a frequency converter (CVCF).
It is intended for server rooms, automation systems, medical and industrial sites with three-phase supply. Paralleling several units increases capacity or provides N+1 redundancy.
The UPS works with UPSGTS31EMBRT 209 external battery modules or STB cabinets. Example runtimes are in the specification table; our Sales Department will size the configuration.
Technical data according to the GT UPS datasheet (version 01.26). Please consult our Sales Department before ordering.